What Is a Truss Roof? How It Works Under Ontario Code
What is a truss roof? Factory-built triangle frames that span wall to wall. How they work, how they differ from rafters, and the Ontario Building Code rules.
What is a truss roof? It is a roof carried by factory-built triangular frames, called trusses, that span from one exterior wall to the other. Each truss holds the roof sheathing above and the ceiling below as one engineered assembly, so the roof does not depend on interior walls to stay up.
That is the short answer, and in the GTA it describes most new houses, garages and additions. Below we explain the parts of a truss, how it differs from rafters, what the Ontario Building Code requires, and what to check before you cut, drill or remove anything. If you are planning a roof, see our roof and truss framing service.
How does a truss roof work?
A truss roof works by turning a load into straight pushes and pulls inside a triangle. The top chords are pushed together, the bottom chord is pulled tight, and the web members in between carry the forces across, so the truss presses straight down on the walls and does not push them outward.
A rafter roof gets the same result with separate pieces: rafters, ceiling joists acting as ties, and a ridge or a bearing wall. In a truss, the plant joins every piece with metal connector plates, so the frame arrives ready to lift. The Canadian industry guide published by the Truss Plate Institute of Canada (TPIC) notes that trusses must stand in the vertical plane to carry load, and that they are laterally unstable until braced. See the TPIC handling, erection and bracing guide.
| Part | What it does |
|---|---|
| Top chord | The sloping outer member that carries the roof sheathing, roofing and snow |
| Bottom chord | The horizontal member that carries the ceiling and ties the two heels together |
| Web members | The diagonal and vertical pieces that brace the chords against each other |
| Connector plates | The metal plates, pressed into both faces at each joint, that hold the pieces together |
| Heel | The point at the wall where the top and bottom chords meet and the truss bears |
What does the Ontario Building Code say about trusses?
Article 9.23.14.11 of the Ontario Building Code says wood roof trusses shall be designed in accordance with good engineering practice, such as the TPIC 2019 truss design procedures. The joints must also meet Subsection 4.3.1, the Code's wood design requirements. We checked the text in the 2024 Building Code compendium, Part 9 in November 2026.
The Code puts several other rules on trusses in houses and small buildings:
- Bracing. Article 9.23.14.11 requires all member bracing to be installed as shown on the truss design drawings, with continuous lateral bracing anchored to the roof and ceiling diaphragms at intervals no greater than 6.10 m.
- No cutting. Article 9.23.5.5 says truss members shall not be notched, drilled or otherwise weakened unless the truss design allows for it.
- Attic load. Article 9.4.2.4 requires truss bottom chords over a residential attic with limited access to be designed for a total specified load of not less than 0.35 kPa.
- Snow load. Article 9.4.2.2 sets the specified snow load from the Ministry's Supplementary Standard SB-1 climatic data for your municipality, and never less than 1 kPa.
- Connection to the wall. Table 9.23.3.4 lists three 82 mm nails to toe-nail a roof truss to the wall plate.
What is the difference between a truss and a rafter roof?

The main difference is where the roof is built. A truss is made in a plant to an engineered design and lifted into place, while a rafter roof is cut and assembled on site from individual boards. Trusses usually span the whole building without interior bearing walls, and rafter roofs usually do not.
| Truss roof | Rafter roof | |
|---|---|---|
| Where it is made | In a plant, to a design for your roof | On site, from lumber cut by the framer |
| Design | Engineered, with drawings from the supplier | Sized from the Code span tables in Part 9 |
| Ceiling below | Bottom chord carries it | Ceiling joists, or a rafter that is a roof joist |
| Attic space | Mostly filled with web members | Open, can be usable |
| Changing it later | Needs the truss supplier or an engineer | Possible, with proper ties and a design |
| Interior walls | Often not load bearing, but must be confirmed | Often carry the ridge or purlins |
Neither one is better in every case. Our stick-built vs truss roofs guide covers the choice, and our roof joist vs roof rafter guide covers how the Code treats rafter roofs. To compare spans for a rough check, try the truss vs rafter span checker.
What are the common types of roof truss?
Trusses are named by their shape. A common truss has a peak and a flat bottom chord, which is the shape in the diagram above. A scissor truss has bottom chords that slope up from the walls, which gives a vaulted ceiling. A gable end truss sits at each end of the roof to support the end wall and the sheathing.
Others include a mono truss, which has one sloping top chord, and a girder truss, which is built heavier to carry other trusses. A truss is designed for one span, pitch and load, so the shape is always chosen on the drawings, not in the field.
How far apart are trusses spaced?
Trusses are normally spaced 24 inches (610 mm) on centre, according to the TPIC erection guide. The spacing on the truss drawings governs your roof, because it sets the load on each truss and the support the roof sheathing needs.
The spacing also decides how thick the sheathing must be. Our OSB for roof sheathing guide shows how Part 9 relates panel thickness to support spacing.
Can you remove a wall under a truss roof?

Often, yes, but you cannot assume it. A truss usually bears on the exterior walls, so interior walls under it are often partitions. Some trusses are designed to bear on an interior wall, and a girder truss can load a beam or post, so the truss drawings and an inspection of the attic decide it.
The Building Code's lintel tables assume a maximum roof truss span of 9.8 m. They allow spans to be increased by 5% if truss spans are not more than 8.6 m, and by 10% if not more than 7.4 m. This is one reason the span on the drawings matters when an opening is cut in a bearing wall. Our guides on how to tell if a wall is load bearing and structural beam installation explain the next steps.
What mistakes do builders and owners make with trusses?
- Cutting a truss for a pipe, duct or hatch. This weakens a member, and the Code forbids it unless the design allows it.
- Releasing the banding before bracing is in place. The TPIC guide warns that trusses may domino, lose lateral stability or collapse if temporary braces are not in place before the bands are cut.
- Leaving out permanent bracing. The bracing on the drawings is part of the design, not an extra.
- Storing heavy loads on the bottom chord. Bottom chords are designed for a ceiling and, over a restricted attic, for a stated load of 0.35 kPa, not for storage.
- Adding load later. A new dormer, a heavy unit or an extra layer of roofing changes the load the truss was designed for.
Checklist: what to have ready before you ask for a quote
- The building plan and the roof pitch you want, or the permit drawings.
- Whether you want a usable attic, a vaulted ceiling or neither, since that changes the truss type.
- Photos of the existing roof framing in the attic with a tape visible for scale, if this is an addition or a change.
- The truss drawings, if the roof already has them.
- Your municipality's permit requirements and snow load.
Next step

For a new roof, an addition or a change to existing roof framing, see our roof and truss framing service, or our home addition framing service if the roof is part of a larger build. To ask for a written quote, contact us with the plans, the roof span and any photos of the attic.
This guide draws on the 2024 Ontario Building Code compendium, Part 9, checked in November 2026 (Articles 9.4.2.2, 9.4.2.4, 9.23.5.5 and 9.23.14.11, Table 9.23.3.4 and the lintel table notes), and on the TPIC guide cited above. Check your own permit drawings and your municipality's rules before you build.
Frequently asked questions
What is a truss roof?
A truss roof is a roof carried by factory-built triangular frames, called trusses, set on the exterior walls about 24 inches apart. Each truss has top chords, a bottom chord and web members, so it carries the roof load as a single unit instead of as separate rafters and ceiling joists.
What is the difference between a truss and a rafter?
A rafter is a single sloping board that is cut and nailed on site, and it depends on ceiling joists and a ridge to stay in place. A truss is a complete frame built in a plant to an engineered design, so its parts work together as one assembly. We compare the two in detail in our guide to roof joists and rafters.
Can you cut or drill a roof truss?
No, not on your own. Article 9.23.5.5 of the Ontario Building Code says roof truss members shall not be notched, drilled or otherwise weakened unless the truss design allows for it. If a pipe, duct or opening has to pass through, the truss supplier has to redesign the truss.
Is a truss roof load bearing?
A truss roof usually rests on the exterior walls, and the interior walls under it are often not load bearing. That is not guaranteed, because a truss can be designed to bear on an interior wall too. Check the truss drawings, and have a framer or engineer confirm it before any wall is touched.
Do trusses need bracing?
Yes. Article 9.23.14.11 requires all member bracing to be installed as shown on the truss design drawings, and continuous lateral bracing to be anchored to the roof and ceiling diaphragms at no more than 6.10 m on centre. Trusses are also unstable until braced during erection.
Do trusses need an engineer in Ontario?
The Building Code requires wood roof trusses to be designed by good engineering practice, such as the TPIC 2019 truss design procedures, and the plant normally supplies stamped drawings with the order. A separate engineer is usually needed only for an unusual roof, a large span or a changed load.