Built to plan
Framed from your architectural and engineered drawings, to the plan and the Ontario Building Code, not by rule of thumb.
Metal stud framing in Toronto and across the GTA, built to your drawings and the Ontario Building Code. Timberr Framing is licensed, insured and WSIB-covered, rated 5.0 on Google, with a workmanship warranty behind every job.
Send the drawings, or just the address and what you are building. We will tell you what is missing before we price it.
Framed from your architectural and engineered drawings, to the plan and the Ontario Building Code, not by rule of thumb.
Engineered lumber, LVL/PSL beams, and connectors chosen for the spans and loads on the plans.
Send specs, drawings, or photos and get a free, no-obligation site visit and estimate with no guesswork.
Installation and site work completed in accordance with Ontario requirements.
Send the drawings, or just the address and what you are building. We will tell you what is missing and what happens next.
We have worked with Timberr Framing on a few projects, and they continue to impress with their great workmanship and reliable service in our commercial unit. We highly recommend them for all your metal stud framing needs!
I was impressed by Timberr Framing’s skilled craftsmanship during our commercial framing project. They delivered high-quality work and maintained strong structural integrity in our commercial development that required metal framing.
The responsive and reliable team at Timberr Framing handled our metal stud framing with precision in our commercial building! Their industry expertise and strong workmanship made the project a success.
We needed metal stud framing for our office, and Timberr Framing delivered. Their team was professional, skilled, and got the job done quickly without sacrificing quality.
Toronto Building administers permits and inspections for the address. Permit-approved drawings must be available on site for inspection. A street-occupation permit applies when materials, equipment, a crane or a disposal container occupies a road, sidewalk, boulevard or public lane.
Toronto warns that covered work may have to be uncovered, so the metal-stud package stays open through booked inspection.
At the address, we verify partition lines, openings, head details and backing. We also confirm how studs, track, board interfaces and occupied-site access will reach and move through the work area. The quote separates wall length, height, gauge, spacing, openings, ratings, backing and access. Any unresolved drawing, access or inspection condition is named instead of being priced as if it were settled.
A Part 9 non-loadbearing partition can use the prescriptive stud tables only within their stated wall-height, spacing, finish and material assumptions. That means your engineer may need to settle the load path before material is ordered.
Loadbearing cold-formed steel framing is not a heavier version of the Part 9 partition table; it requires Part 4 design. That means your quote carries the matching member layout, connector schedule and site handling.
Exterior non-loadbearing steel studs have a separate size, thickness, spacing and maximum-length table from interior partitions. That means you get the route supported by the drawings instead of a choice made from habit.
A fire-rated partition is governed by its complete assembly, including head clearance, board layers, fasteners, openings and penetrations, rather than stud depth alone. That means your following trades inherit that system's spacing, openings and limits.
Failure: treating a loadbearing steel wall as a Part 9 partition. Prevention: identify loadbearing status and require the Part 4 design before procurement, which means you do not inherit that condition after it is concealed. Failure: selecting studs from depth alone while ignoring height, spacing or metal thickness. Prevention: check every table input and the assembly assumptions, which means you can correct the load path or assembly while the work remains accessible.
Failure: fixing fire-rated studs tightly to the top runner. Prevention: preserve the specified head clearance and attachment condition, which means your approved repair is documented before the next trade arrives. We stop a conflict involving a part 9 non-loadbearing partition because you need the designer's answer before an improvised fix becomes permanent.
Steel studs and runners within OBC Section 9.24 must conform to the product standard named in Article 9.24.1.2. That means your installed member must match the grade or product shown in the design. The metal thickness stated in Section 9.24 is minimum base-steel thickness and excludes coatings, which means you can verify the material condition before it is enclosed.
Non-loadbearing interior studs covered by the prescriptive provision require a base-steel thickness of at least 0.46 mm unless the opening rules require more. That means your bearing and connection detail must preserve that capacity. Interior and exterior runners must be at least as thick as their corresponding studs and must have flanges at least 30 mm deep. That means you can trace the fastening requirement to the actual assembly.
Permit applications for non-residential alterations require scaled, dimensioned, signed and dated drawings. Professional general-review commitments can be required where the Code calls for professional design and field review. That means your sequence must reach that visible hold point before finishes. The permit holder is responsible for contacting the municipality when the work reaches a prescribed inspection stage such as structural framing. That means you can plan the following trade around the stated response.
Board installers inherit stud alignment, spacing, supported corners and edges, screw substrate and the required rated-assembly geometry. That means your mechanical and electrical work may have to be complete before the framing review. Door and glazing installers inherit the opening width, height, jamb build-up and header condition established by the framing. That means you avoid reopening work the municipality needed to see.
Floor plans, reflected-ceiling plans, wall-type schedule and full-height details, which means you give the estimator the current design basis. Occupancy, permit scope, fire-resistance and acoustic requirements for every wall type, which means your takeoff can include the scheduled members and openings. Add the address, permit status and target start window, so you can separate what is ready to price from what still needs a decision.
Ours names what we frame, what another trade supplies, and what has to be settled before we mobilise. Compare the scope, not two totals built on different assumptions.
Clean framing, tight sequencing, and a tidy site, coordinated with concrete, drainage, openings, and surrounding trades, and completed to code where site work is in scope.
It depends on whether the scope is permit work. Toronto requires a building permit for a new building, an addition and structural alterations.
The issued permit package and the work for that inspection stage must be ready. Keep the permit-approved drawing set on site and keep permit work visible for its required inspection.
Only when the applicable municipal approval allows it. A street-occupation permit is required when the delivery, crane, bin or material storage occupies the public right of way, including a public lane.
Send the address, current architectural and structural drawings, permit status and clear site photos. For this scope, the quote also needs wall length, height, gauge, spacing, openings, ratings, backing and access plus the proposed route for studs, track, board interfaces and occupied-site access.
Most are not, and that is fine. Send what you have and we will tell you what is missing before it costs you a week on site.
Framing services across Toronto. See all framing in Toronto →
Custom homes, additions, renovations, and multiplexes, framed on site for builders, homeowners, contractors, and property teams.
Send the current drawings, property address, permit status and target start. We will check the package around a part 9 non-loadbearing partition, so you can resolve a missing structural, access or coordination decision before it becomes a site delay.
Backed by our workmanship warranty, we stand behind every job · Licensed, Insured & WSIB-Covered
Send the drawings, or just the address and what you are building. We will tell you what is missing before we price it.
Timberr Framing provides metal stud framing, built to plan with quote-ready support across Toronto and surrounding Ontario communities.
Companies We've Worked With
Timberr Framing supports plan-based framing for commercial, institutional, property, and builder-led projects across Toronto and Ontario.