Built to plan
Framed from your architectural and engineered drawings, to the plan and the Ontario Building Code, not by rule of thumb.
Rough framing in King City and across the GTA, built to your drawings and the Ontario Building Code. Timberr Framing is licensed, insured and WSIB-covered, rated 5.0 on Google, with a workmanship warranty behind every job.
Send the drawings, or just the address and what you are building. We will tell you what is missing before we price it.
Framed from your architectural and engineered drawings, to the plan and the Ontario Building Code, not by rule of thumb.
Engineered lumber, LVL/PSL beams, and connectors chosen for the spans and loads on the plans.
Send specs, drawings, or photos and get a free, no-obligation site visit and estimate with no guesswork.
Installation and site work completed in accordance with Ontario requirements.
Send the drawings, or just the address and what you are building. We will tell you what is missing and what happens next.
Timberr Framing did an excellent job with our commercial units! We'll definitely be using them again for future projects!
We have worked with Timberr Framing on a few projects, and they continue to impress with their great workmanship and reliable service in our commercial unit. We highly recommend them for all your metal stud framing needs!
Highly recommend to anyone with a stacked townhome project! Outstanding craftsmanship once again Timberr Framing.
I was impressed by Timberr Framing’s skilled craftsmanship during our commercial framing project. They delivered high-quality work and maintained strong structural integrity in our commercial development that required metal framing.
Timberr Framing’s team was not only punctual and dependable but also demonstrated exceptional skills in both addition and commercial framing projects. We'll definitely hire them again!
Timberr Framing has an efficient process and always completes work on time. Their team is highly organized, and our team of developers are always satisfied with the final results.
King City addresses use the Township of King Building Division. The permit package includes an inspection notice sheet listing mandatory stages. Vehicles, materials or equipment in a Township right of way can require a road-occupancy permit.
King requires inspected work to remain visible and may order covered elements uncovered, so the rough frame stays accessible through inspection. Lot grading, stormwater and servicing are reviewed separately from the Building Division final.
At the address, we verify bearing lines, floor elevations, openings and bracing. We also confirm the current municipal approval status and the route for lumber, panels, trusses and lifting access. That route is checked without assuming municipal road space is available.
The quote separates floor area, storeys, spans, openings, roof form and access, together with any road, grading, heritage or inspection condition triggered at this property. Timberr schedules the project from the GTA or York Region after those inputs are settled. Unresolved design and access conditions remain named rather than hidden inside the framing allowance.
Sawn-lumber joists and rafters use the Part 9 span tables only after species, grade, depth, spacing, loading and support condition are identified. That means your engineer may need to settle the load path before material is ordered.
Ontario recognizes I-joists, metal-web wood joists and plated wood trusses as lightweight pre-engineered systems, which means your quote carries the matching member layout, connector schedule and site handling.
Engineered and prefabricated wood systems can include wall panels, floor panels and roof trusses. But project layouts and product instructions control their installation, which means you get the route supported by the drawings instead of a choice made from habit.
Site-framed rafters are a distinct roof system from trusses and must fit the relevant span, ridge, valley, hip, collar-tie and support provisions. That means your following trades inherit that system's spacing, openings and limits.
The first floor deck can be square to itself and still be wrong to the foundation. Copy that offset upward and the roof, openings and cladding inherit it on every level. We check the foundation and bearing controls before the first deck becomes the reference for the rest of the build.
Loadbearing studs require Stud, Standard or No. 2 grade; non-loadbearing studs may use Stud, Utility or No. 3, which means your installed member must match the grade or product shown in the design. Installed framing lumber may contain no more than 19 percent moisture, which means you can verify the material condition before it is enclosed.
Floor joists require at least 38 mm of end bearing unless supported on ribbon boards, which means your bearing and connection detail must preserve that capacity. Beam ends require at least 89 mm of even, level bearing unless a span-table note permits otherwise. That means you can trace the fastening requirement to the actual assembly.
Ontario requires notice when Part 9 structural framing and heating and air-conditioning ductwork and piping are substantially complete. That means your sequence must reach that visible hold point before finishes. The prescribed inspection response is 2 days after notice, excluding weekends, holidays and closed-office days, which means you can plan the following trade around the stated response.
Mississauga requires plumbing, electrical and HVAC rough-ins to pass before the framing inspection is booked. That means your mechanical and electrical work may have to be complete before the framing review. Mississauga checks structure and openings against the drawings, fire blocking, ceiling heights, rooms and windows while framing is uncovered. That means you avoid reopening work the municipality needed to see.
Request complete architectural and structural sets, including current revisions, opening schedules and design notes, which means you give the estimator the current design basis. Request floor layouts, beam and post schedules, roof or truss layouts and engineered-product details, which means your takeoff can include the scheduled members and openings. Add the address, permit status and target start window, so you can separate what is ready to price from what still needs a decision.
Ours names what we frame, what another trade supplies, and what has to be settled before we mobilise. Compare the scope, not two totals built on different assumptions.
Clean framing, tight sequencing, and a tidy site, coordinated with concrete, drainage, openings, and surrounding trades, and completed to code where site work is in scope.
Yes, when the drawings, site access and schedule support the project. Timberr takes on suitable King City work from its GTA and York Region service base, with mobilisation tied to the booked address.
It depends on whether the proposed scope is permit work. Township of King Building, not York Region, administers the King City permit and inspections.
The issued permit package and the work assigned to that inspection stage must be ready. Keep inspected work visible and follow the mandatory stages on the King permit notice sheet.
Unresolved access approval or an incomplete material route can delay mobilisation. A road-occupancy permit can apply to vehicles, materials or equipment placed in a Township right of way. The quote also needs floor area, storeys, spans, openings, roof form and access.
Most are not, and that is fine. Send what you have and we will tell you what is missing before it costs you a week on site.
Framing services across King City. See all framing in King City →
Custom homes, additions, renovations, and multiplexes, framed on site for builders, homeowners, contractors, and property teams.
Before the King City structural shell handoff, send the drawings, address, timing, and known site conditions. For the King City structural shell crew, Timberr will identify what the scope needs for a reliable quote and framing schedule.
Backed by our workmanship warranty, we stand behind every job · Licensed, Insured & WSIB-Covered
Send the drawings, or just the address and what you are building. We will tell you what is missing before we price it.
Timberr Framing provides rough framing, built to plan with quote-ready support across Toronto and surrounding Ontario communities.
Companies We've Worked With
Timberr Framing supports plan-based framing for commercial, institutional, property, and builder-led projects across Toronto and Ontario.